Information Sheet
TROLL
®
Accessories
0085192 12/08
TROLL
®
Shield antifouling guard
Catalog Number 0085190
OVERVIEW
The TROLL
®
Shield antifouling guard is designed to reduce fouling of the
conductivity cell on Aqua TROLL
®
100 and 200 instruments. Reduced fouling on
the sensor improves measurement accuracy and extends the length of instrument
deployments. For optimum performance, replace the coil every 6 months.
INSTRUCTIONS
Loosen the black coupler, but do not remove it.1.
Slide the guard over and past the nose cone so that it covers the conductivity cell.2.
Align the guard so that water can flow freely through the copper wire and 3.
through the conductivity cell. Hold the guard and instrument up to the light to
make sure that water can freely pass through.
Tighten the black coupler.4.
Guard
Note how light (and water)
can pass through the coils
and the conductivity cell.
Black coupler
Optional copper nose cone
OTHER ACCESSORIES
Foam swabs for cleaning Aqua TROLL
®
conductivity cells ...........................0056820
Alconox
®
cleaning solution .............................................................................0029810
TROLL
®
Shield nose cone for Level TROLL
®
and Aqua TROLL
®
instruments .....................................................................0085190
Cleaning Tips
Remove the coil and clean with a soft •
brush to remove macrofouling.
Clean the nose cone and conductivity •
sensor as described in the Aqua TROLL
operator's manual.