0051120 | Rev. 008 | 09/2013
Level TROLL
®
400, 500, 700, and 700H
In order to deploy the instrument, complete the following
steps.
l Connect the instrument to a computer or
RuggedReader.
l Connect the instrument to the software and set up a
site and a data log.
l Install the instrument in the water. (If you are using a
level reference set it at this time.)
l Verify the installation position then disconnect the
instrument from the computer or RuggedReader.
l Secure the cable and install the desiccant.
Select a TROLL Com Communication
Device
The subsequent figure shows the function and connection
features of the TROLL Com Communication Device
models.
l A Direct-Connect TROLL Com might be preferred
for programming an instrument that will be deployed
on a suspension cable.
l A RuggedCable System and a Cable-Connect
TROLL Com are required if you intend to
communicate with the instrument while it is
deployed. However, you can program the instrument
with any TROLL Com.
l A serial (RS232) TROLL Com is required for use
with a RuggedReader Handheld PC.
1
Serial port on a PC/laptop and RuggedReader
Handheld PC
2
Cable-Connect TROLL Com Communication
Device, serial connection, for field use
3
Direct-Connect TROLL Com Communication
Device, serial connection, programming only, not
submersible
4
USB port on a PC/laptop
5
Direct-Connect TROLL Com Communication
Device, USB connection, programming only, not
submersible
6
Cable-Connect TROLL Com Communication
Device, USB connection, for field use
Connecting the RuggedCable System
Connect the Instrument to the RuggedCable
System
1. Remove the protective caps from the instrument and
cable. Ensure that the O-ring on the instrument
connection is clean.
2. Locate the flat side of each connector and notice the pins
on the instrument connector and the slots on the cable
connector.
3. Slide back the sleeve on the cable connector.
4. Position the instrument and cable flat edges so they will
connect properly. Insert the instrument connector firmly
into the cable connector.
5. Slide the cable sleeve toward the instrument until the pin
on the instrument fits into the hole in the slot on the cable
connector.
6. Hold the textured section of the sleeve in one hand and
the instrument in the other. Push and twist until you hear
a click. The click ensures the cable and instrument are
securely attached.
Connect TROLL Com Communication Device to
the RuggedCable System
1. If a desiccant is present, remove the desiccant from the
cable. Hold the textured section of the cable connector in
one hand and the desiccant in the other. Twist in
opposite directions to unlock the desiccant from the
cable.
2. Position the TROLL Com and the cable flat edges so
they will connect properly. Insert the TROLL Com
connector firmly into the cable connector.
3. Hold the textured section of the sleeve in one hand and
the TROLL Com in the other. Push and twist until you
hear a click. The click ensures the cable and TROLL
Com are securely attached.
Field Deployment
Program the Instrument
In order to set up a log or download data, you must
connect the instrument to a computer running Win-Situ 5
Software, or a RuggedReader Handheld PC running Win-
Situ Mobile. Refer to the Win-Situ 5 or Win-Situ Mobile
section. See page 2.
Position the Instrument
Place the instrument at the desired depth. Position the
instrument below the lowest anticipated water level, but
not so low that the pressure sensor range might be
exceeded at the highest anticipated water level. Refer to
the tables below to determine usable depth.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 0051120

0051120 | Rev. 008 | 09/2013Level TROLL®400, 500, 700, and 700HIn order to deploy the instrument, complete the followingsteps.l Connect the instrument

Page 2 - Win-Situ 5 Software

Information subject to change without notice. In-Situ, In-Situ logo, Baro Merge, BaroTROLL, HERMIT, iSitu, Pocket-Situ, RDO, RuggedCable, RuggedReader

Page 3 - Downloading Data to a PC

0051120 | Rev. 008 | 09/2013instrument clock to the PC clock.Parameters and measurements are displayed in light grayon the home screen if a connection

Page 4 - Win-Situ Mobile Software

Information subject to change without notice. In-Situ, In-Situ logo, Baro Merge, BaroTROLL, HERMIT, iSitu, Pocket-Situ, RDO, RuggedCable, RuggedReader

Commentaires sur ces manuels

Pas de commentaire